User-defined tools had no way to read reference data installed through
tool data tables. A `reference_data` input offers a table's entries as
a select and hands the chosen entry to expressions like a dataset, with
`path`, `basename`, `source` and the table's other columns under
`metadata`. `multiple: true` supplies a list of entries.
It has its own parameter model, ReferenceDataParameterModel
(gx_reference_data), which runtimeify, the YAML v1 parameter allowlist
and the test case conversions match on. The tool form renders it as a
select.
GalaxyUserTool can only read tables an admin marked `user_accessible`,
checked on the form and again when the job runs. Admin-installed
GalaxyTool YAML tools can read every table.
Refs #22700